Monthly FOS Trending Report:  Day 94.241:00:00 - 94.275:23:59						
						
				Cycle Summary				
			This Period	Total Since Launch	Design Lifetime	
			Cycles	Hours	Cycles	Hours		Cycles	Hours
SAFE			0	0.00	30	1954.11		n/a	n/a
HOLD			n/a	385.21	n/a	19653.69	n/a	n/a
Red LV			14	174.53	573	5328.42		~	~
Blue LV			13	280.26	601	7370.17		~	~
Red HV			19	85.48	687	3347.15		~	~
Blue HV			27	100.42	809	3945.42		~	~
Cal lamp A		9	0.13	596	22.08		~	500 hours
Cal lamp B		16	0.14	1498	20.88		~	500 hours
Taled/Ion		5	0.34	608	205.78		~	~
Ent Door		260	n/a	8205	n/a		20000	  n/a
Apt Wheel		106	n/a	4012	n/a		30k (90)   n/a
FGW 			175	n/a	5831	n/a		54k (90)   n/a
Pol Wheel		201	n/a	2497	n/a		100k(22.5) n/a
Red anomolous uP resets	  0	n/a	1	n/a		n/a	   n/a
Blue spurious  uP resets  1	n/a	48	n/a		n/a	   n/a
Blue anomolous  uP resets 0	n/a	1	n/a		n/a	   n/a
						
					Voltage and Current Summary  (This Period)					
					Low Lim	Minimum	Average	Maximum	High Lim	
Red side Logic Supply (Volts)		4.83	0.52	4.94	4.97	5.03	
Red side Quiet Supply (Volts)		7.80	7.04	8.01	8.05	8.20	
Red side High Voltage (KVolts)		~	0.29	10.80	22.84	~	
Red side High Voltage Cur (uAmps)	~	0.1	11.02	23.53	~	
Red  Discriminator Voltage (Volts)	~	0.02	4.09	4.98	~	
Blue side Logic Supply (Volts)		4.87	0.52	4.94	4.97	5.07	
Blue side Quiet Supply (Volts)		7.80	7.04	8.02	8.05	8.20	
Blue side High Voltage (KVolts)		~	0.29	11.37	22.84	~	
Blue side High Voltage Cur (uAmps)	~	0.2	11.58	23.53	~	
Blue  Discriminator Voltage (Volts)	~	0.02	4.09	4.98	~	
Calibration lamp A voltage (volts)	~	210.34	211.33	212.32	~	
Calibration lamp A current (uAmps)	8.00	10.41	10.41	10.41	12.00	
Calibration lamp B voltage (Volts)	~	208.35	209.53	210.34	~	
Calibration lamp B current (uAmps)	8.00	10.41	10.41	10.41	12.00	
						
				Miscellaneous  Summary					
				This Period		Since Launch^			
				Max		Total		Max	T	otal		Max Limit	Total Limit
Red Total Accumulated Counts	4.07E+07	3.60E+09	4.03E+08	5.46E+10	1.20E+08	1.00E+15
Blue Total Accumulated Counts	1.56E+07	6.53E+08	5.12E+07	5.40E+10	1.20E+08	1.00E+15
Overlite Red SAA		2.23E+05	4.52E+06	2.69E+08	1.35E+09	1.20E+08	n/a
Overlite Blue SAA		5.19E+06	9.88E+06	3.61E+07	1.03E+14	1.20E+08	n/a
						
	Detector Dark Count Summary (This Period)					
	
			Max (Cnts)	Avg (Cnts)	Std. Dev. 	Time (hrs)	New Bad Chnls	Tot Bad Chnls
Red Dark Counts		1.99E+03	3.27E+02	156.38		24.65		0		15
Blue Dark Counts	1.84E+03	2.47E+02	145.37		24.03		0		26
						
Limits defined as nominal operating limits, not action or health and safety limits.						
~  Engineering Data Analysis not fully defined at this time.: n/a Not Applicable						
   Total hours since Nov 1,1990 only  : ^ Total since April 1, 1991 only. 						
						
Table FOS-T1: September 1994 Cycle and Voltage Summary