Monthly FOS Trending Report:  Day 94.332:00:00 - 95.001:23:59						
						
			Cycle Summary				
			This Period	Total Since Launch	Design Lifetime	
			Cycles	Hours	Cycles	Hours 	Cycles	Hours
SAFE			2	121.5	34	2139.23		n/a	n/a
HOLD			n/a	255.27	n/a	20793.43	n/a	n/a
Red LV			16	347.44	611	5948.70		~	~
Blue LV			14	115.79	637	7777.03		~	~
Red HV			26	155.50	750	3615.19		~	~
Blue HV			19	80.45	865	4153.57		~	~
Cal lamp A		14	0.17	633	23.43		~	500 hours
Cal lamp B		43	0.44	1580	22.66		~	500 hours
Taled/Ion		2	0.11	611	205.95		~	~
Ent Door		273	n/a	8782	n/a		20000	    n/a
Apt Wheel		122	n/a	4269	n/a		30k (90¡)   n/a
FGW 			207	n/a	7309	n/a		54k (90¡)   n/a
Pol Wheel		2	n/a	2499	n/a		100k(22.5¡) n/a
Red anomolous uP resets	x	n/a	1	n/a		n/a	n/a
Blue spurious  uP resetsx	n/a	48	n/a		n/a	n/a
Blue anomolous  uP resetx	n/a	1	n/a		n/a	n/a
						
					Voltage and Current Summary  (This Period)					
					Low Lim	Minimum	Average	Maximum	High Limit	
Red side Logic Supply (Volts)		4.83	4.90	4.92	4.97	5.03	
Red side Quiet Supply (Volts)		7.80	7.89	7.97	8.05	8.20	
Red side High Voltage (KVolts)		~	21.47	21.85	21.86	~	
Red side High Voltage Cur (uAmps)	~	22.75	23.19	23.53	~	
Red  Discriminator Voltage (Volts)	~	4.08	4.10	4.12	~	
Blue side Logic Supply (Volts)		4.87	4.93	4.96	5.00	5.07	
Blue side Quiet Supply (Volts)		7.80	7.95	8.03	8.05	8.20	
Blue side High Voltage (KVolts)		~	21.37	22.76	22.84	~	
Blue side High Voltage Cur (uAmps)	~	21.18	22.70	23.14	~	
Blue  Discriminator Voltage (Volts)	~	4.00	4.24	4.24	~	
Calibration lamp A voltage (volts)	~	210.34	211.80	212.32	~	
Calibration lamp A current (uAmps)	8.00	10.41	10.43	10.47	12.00	
Calibration lamp B voltage (Volts)	~	208.35	209.94	212.32	~	
Calibration lamp B current (uAmps)	8.00	10.41	10.42	10.47	12.00	
						
				Miscellaneous  Summary					
				This Period			Since Launch^			
				Max		Total		Max		Total		Max Limit	Total Limit
Red Total Accumulated Counts	9.04E+07	2.23E+09	4.03E+08	6.06E+10	1.20E+08	1.00E+15
Blue Total Accumulated Counts	5.27E+07	1.13E+09	5.27E+07	5.71E+10	1.20E+08	1.00E+15
Overlite Red SAA		2.50E+06	9.47E+06	2.69E+08	1.50E+09	1.20E+08	n/a
Overlite Blue SAA		1.91E+07	3.37E+07	3.61E+07	1.03E+14	1.20E+08	n/a
						
	Detector Dark Count Summary (This Period)					
	
			Max (Cnts)	Avg (Cnts)	Std. Dev. 	Time (hrs)	New Bad Chnls	Tot Bad Chnls
Red Dark Counts		1.95E+03	3.34E+02	135.68		62.57		0		15
Blue Dark Counts	1.68E+03	3.01E+02	250.15		24.95		0		26
						
Limits defined as nominal operating limits, not action or health and safety limits.						
~  Engineering Data Analysis not fully defined at this time.: n/a Not Applicable						
   Total hours since Nov 1,1990 only  : ^ Total since April 1, 1991 only. 						
						
Table FOS-T1: December 1994 Cycle and Voltage Summary