Statistics of FOC Analog Monitors (F/96)
Start date: 94335 End date: 94365
SAFE HOLD HV
MSID MIN AVG MAX STD MIN AVG MAX STD LowLim MIN AVG MAX STD HighLim
Temperatures:
X112 16.82 16.85 17.74 0.04 16.82 16.87 17.42 0.10 16.25 16.82 17.03 17.42 0.12 17.74
X124 -23.91 -22.79 -20.87 0.98 -26.96 -22.53 -16.39 1.24 -41.37 -25.22 -20.87 -15.67 2.11 -8.53
X128 7.78 9.46 13.13 0.54 4.95 8.24 15.96 1.70 -15.31 -1.71 3.46 9.19 2.36 20.00
X110 -8.29 -7.35 -6.86 0.82 -9.25 -6.73 -0.18 1.56 -25.65 -8.77 -5.40 -0.18 2.08 13.85
X106 -0.34 0.90 3.37 2.14 -2.62 0.29 6.79 1.53 -10.00 -3.06 0.97 5.30 2.07 20.00
X720******** ******** ******** ******** ******** ******** ******** ******** -99.00 -5.88 9.65 15.71 3.97 26.43
EBA Units HK Voltages:
X134 0.00 0.02 0.02 0.00 0.00 0.02 0.02 0.00 1.46 2.04 2.06 2.08 0.00 2.50
X140 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.62 2.48 2.50 2.52 0.01 3.52
X144 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.00 4.34 4.46 4.50 4.52 0.01 4.88
X148 4.48 4.48 4.48 ******** 4.46 4.48 4.48 0.00 4.36 4.46 4.48 4.48 0.00 4.60
X150 3.90 3.90 3.90 ******** 3.86 3.90 4.02 0.01 3.76 3.92 4.03 4.18 0.01 4.68
Detector Power Control Unit (PCU)
X154 0.15 0.18 0.18 0.00 0.15 0.15 0.18 0.00 2.20 2.20 2.55 3.37 0.03 5.06
X156 24.08 24.31 24.50 0.16 23.66 24.31 27.72 0.08 26.32 27.58 27.83 28.00 0.03 29.40
X726 0.00 0.00 0.00 0.00 0.00 0.00 0.56 0.00 0.00 0.00 0.17 1.28 0.04 6.00
Detector Power Supplies:
X162 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 4.90 5.15 5.18 5.18 0.00 5.53
X164 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 14.36 15.06 15.10 15.12 0.01 15.56
X166 -99.90 -99.90 -99.90 0.00 -99.90 -99.90 -99.90 0.00 -15.48 -14.95 -14.95 -14.95 0.00 -14.43
X168 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 27.06 27.73 27.84 27.84 0.00 99.99
X172 -9.99 -9.99 -9.99 0.00 -9.99 -9.99 0.11 0.00 1.50 1.58 1.68 1.87 0.01 2.09
High Voltage P/S:
X800 -9.99 -9.99 -9.99 0.00 -9.99 -9.99 -9.99 0.00 10.18 10.47 10.47 10.49 0.00 10.59
X808 -9.99 -9.99 -9.99 0.00 -9.99 -9.99 -9.99 0.00 38.23 36.13 36.35 36.35 0.00 38.84
X812 -9.99 -9.99 -9.99 0.00 -9.99 -9.99 -9.99 0.00 10.00 10.76 10.84 10.84 0.00 11.00
Detector Focus Parameter:
X736 -99.90 -99.90 -99.90 0.00 -99.90 -99.90 -99.90 0.00 67.18 70.16 72.56 74.99 0.02 76.86
X738 0.00 0.00 0.00 0.00 0.00 0.01 145.06 0.03 131.40 141.91 143.47 145.06 0.01 161.10
X742 9.99 9.99 9.99 0.00 9.99 9.99 9.99 0.00 -47.10 -47.06 -43.99 -43.67 0.01 -42.40
X748 0.00 0.00 0.00 0.00 0.00 0.05 618.83 0.11 697.00 909.77 923.10 946.71 2.81 1011.00
X750 0.00 0.00 0.00 0.00 0.00 0.00 24.54 0.00 117.30 158.18 161.14 171.81 0.12 182.70
X752 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 6.76 7.12 7.17 7.22 0.00 8.00
Contamination Monitoring:
X158 0.00 0.02 0.02 0.00 0.00 0.00 0.36 0.00 0.00 0.00 0.01 0.02 0.00 3.00
X160 0.16 0.16 0.18 0.00 0.16 0.18 0.32 0.00 0.00 4.48 4.50 4.52 0.00 5.20
SAFE 2.0 cycles 16.9 hrs
F48 lifetime 129.9% HOLD F48 5.0 cycles 201.96 hrs HV F48 1.0 cycles 587.0 total cycles 0.30 hrs 2598.93 total hrs
F96 lifetime 335.8% HOLD F96 8.0 cycles 488.14 hrs HV F96 6.0 cycles 954.0 total cycles 35.32 hrs 6715.04 total hrs
FOC-T1: Engineering Trending and HV statistics