Monthly FOS Trending Report:  Day 94.213:00:00 - 94.240:23:59						
						
				Cycle Summary				
			This Period	Total Since Launch	Design Lifetime	
			Cycles	Hours	Cycles	Hours 	Cycles	Hours
SAFE			0	0.00	30	1954.11		n/a	n/a
HOLD			n/a	287.18	n/a	19268.48	n/a	n/a
Red LV			11	128.53	559	5153.89		~	~
Blue LV			11	256.29	588	7089.91		~	~
Red HV			15	60.67	668	3261.67		~	~
Blue HV			16	88.09	782	3845.00		~	~
Cal lamp A		38	0.39	587	21.95		~	500 hours
Cal lamp B		36	0.41	1482	20.74		~	500 hours
Taled/Ion		3	0.23	603	205.44		~	~
Ent Door		174	n/a	7945	n/a		20000	n/a
Apt Wheel		132	n/a	3906	n/a		30k(90)	n/a
FGW 	168		n/a	5656	n/a	54k 		(90)	n/a
Pol Wheel		68	n/a	2296	n/a	     100k(22.5) n/a
Red anomolous uP resets	  0	n/a	1	n/a		n/a	n/a
Blue spurious  uP resets  0	n/a	47	n/a		n/a	n/a
Blue anomolous  uP resets 0	n/a	1	n/a		n/a	n/a
						
					Voltage and Current Summary  (This Period)					
					Low Lim	Minimum	Average	Maximum	High Lim
Red side Logic Supply (Volts)		4.83	4.90	4.93	5.00	5.03	
Red side Quiet Supply (Volts)		7.80	7.89	7.99	8.05	8.20	
Red side High Voltage (KVolts)		~	21.47	21.86	21.86	~	
Red side High Voltage Cur (uAmps)	~	22.45	23.19	23.53	~	
Red  Discriminator Voltage (Volts)	~	4.08	4.11	4.86	~	
Blue side Logic Supply (Volts)		4.87	4.93	4.96	5.00	5.07	
Blue side Quiet Supply (Volts)		7.80	7.95	8.04	8.11	8.20	
Blue side High Voltage (KVolts)		~	21.37	22.76	22.84	~	
Blue side High Voltage Cur (uAmps)	~	21.27	22.67	23.24	~	
Blue  Discriminator Voltage (Volts)	~	3.98	4.23	4.86	~	
Calibration lamp A voltage (volts)	~	210.34	210.51	212.32	~	
Calibration lamp A current (uAmps)	8.00	10.41	10.41	10.41	12.00	
Calibration lamp B voltage (Volts)	~	208.35	208.60	212.32	~	
Calibration lamp B current (uAmps)	8.00	10.41	10.41	10.41	12.00	
						
					Miscellaneous  Summary					
				This Period		Since Launch^			
				Max		Total		Max		Total		Max Limit	Total Limit
Red Total Accumulated Counts	3.53E+07	5.26E+08	4.03E+08	5.10E+10	1.20E+08	1.00E+15
Blue Total Accumulated Counts	2.04E+07	3.33E+08	5.12E+07	5.34E+10	1.20E+08	1.00E+15
Overlite Red SAA		2.99E+07	4.11E+07	2.69E+08	1.35E+09	1.20E+08	n/a
Overlite Blue SAA		1.71E+07	3.76E+07	3.61E+07	1.03E+14	1.20E+08	n/a
						
				Detector Dark Count Summary (This Period)						
			Max (Cnts)	Avg (Cnts)	Std. Dev. 	Time (hrs)	New Bad Chnls	Tot Bad	Chnls
Red Dark Counts		1.98E+03	3.34E+02	171.63		17.13		0		15
Blue Dark Counts	1.94E+03	2.42E+02	127.42		20.98		0		26
						
Limits defined as nominal operating limits, not action or health and safety limits.						
~  Engineering Data Analysis not fully defined at this time.: n/a Not Applicable						
   Total hours since Nov 1,1990 only  : ^ Total since April 1, 1991 only. 						
						
Table FOS-T1: August 1994 Cycle and Voltage Summary