! $Id: 5077,v 4.1 1994/07/27 15:02:00 pepsa Exp $ coverpage: title_1: FOC/96 SMOV REVERIFICATION PROPOSAL AFTER SM sci_cat: ENGINEERING sci_subcat: CALIBRATION proposal_for: SME/FOC pi_fname: MANFRED pi_lname: MIEBACH pi_inst: STSCI pi_country: USA pi_phone: 301-338-4544 keywords_1: CALIBRATION,ENGINEERING hours_pri: 1.00 foc: Y time_crit: N pi_position: FOC ENGINEER ! end of coverpage abstract: line_1: This proposal implements SMOV activity FOC-7, which line_2: is titled FOC F/96 Initial Operations. The activities line_3: within this proposal will generate a set of internal line_4: images as the first operation of the FOC high voltage line_5: after the servicing mission. These images and the line_6: accompanying engineering telemetry will demonstrate line_7: that the FOC hardware and flight software configuration line_8: are nominal on the F/96 side. In addition the comparison line_9: of these images to similar ones taken prior to the line_10: servicing mission will demonstrate that the FOC electronics, line_11: hardware and science data collection paths still function line_12: correctly when using the F/96 side. ! ! end of abstract general_form_proposers: lname: MIEBACH fname: MANFRED inst: STSCI country: USA ! ! end of general_form_proposers block general_form_text: question: 2 section: 1 line_1: Prior to beginning the Servicing Mission activities line_2: associated with the deployment of the COSTAR, it is line_3: necessary to verify that the FOC is functional. These line_4: observations represent the initial attempt to use the line_5: FOC high voltage after the Servicing Mission. ! question: 3 section: 1 line_1: A series of 4 images will be taken with the FOC 96 relay. line_2: Three of the images will use the internal flat field lamps line_3: and one will be a dark. One of the internal flats will line_4: result in a filter and focusing mechanism change. line_5: The images were chosen to be similar to those done on a line_6: routine basis in order to allow verification that the FOC line_7: is operating properly by visual inspection of the images. ! question: 5 section: 1 line_1: The FOC Tranisition to Hold activity (FOC-5) (proposal 5270) line_2: must have been completed successfully and FOS and GHRS line_3: pressure must be below .5 microTorrs for at least 12 hours line_4: before executing this proposal. ! !end of general form text general_form_address: lname: MIEBACH fname: MANFRED category: PI inst: STScI addr_1: 3700 San Martin Drive city: Baltimore state: MD zip: 21218 country: USA phone: 410-338-4544 ! ! end of general_form_address records ! No fixed target records found ! No solar system records found ! No generic target records found exposure_logsheet: linenum: 1.000 targname: INTFLAT config: FOC/96 opmode: RESEAU aperture: 512X1024 sp_element: CLEAR num_exp: 1 time_per_exp: 15M priority: 1 param_1: PIXEL=50X25, param_2: LED=GREEN-2, param_3: LED-STEP=14 req_1: CYCLE 3 / 1-4; ! linenum: 2.000 targname: INTFLAT config: FOC/96 opmode: RESEAU aperture: 512X1024 sp_element: CLEAR num_exp: 1 time_per_exp: 15M priority: 1 param_1: PIXEL=50X25, param_2: LED=GREEN-2, param_3: LED-STEP=14 ! linenum: 3.000 targname: DARK config: FOC/96 opmode: IMAGE aperture: 512X1024 sp_element: CLEAR num_exp: 1 time_per_exp: 15M priority: 1 param_1: PIXEL=50X25, ! linenum: 4.000 targname: INTFLAT config: FOC/96 opmode: RESEAU aperture: 512X1024 sp_element: PRISM2,F342W num_exp: 1 time_per_exp: 15M priority: 1 param_1: PIXEL=50X25, param_2: LED=GREEN-2, param_3: LED-STEP=14 ! ! end of exposure logsheet ! No scan data records found