! File: 5009C.PROP ! Database: PEPDB ! Date: 23-FEB-1994:14:51:27 coverpage: title_1: ST FOCUS INVESTIGATION proposal_for: ENG pi_title: DR. pi_fname: VICKI pi_lname: BALZANO pi_inst: SPACE TELESCOPE SCIENCE INSTITUTE pi_country: USA pi_phone: 410-338-4736 wf_pc: Y foc: Y ! end of coverpage abstract: line_1: The aim of this prop is to investigate the cause of ST focus changes line_2: over an orbit using the FOC and the PC. The overall goal is to take line_3: as many observations as possible of a point source with an optimum line_4: s/n ratio with both of the cameras over the period of one orbit. line_5: For the benefit of short FOC exp times, a small FOC detector format line_6: will be used 256x256. In order to ensure, however, that the target line_7: is indeed well centered in this small FOV a Mode I TA procedure has line_8: to be scheduled prior to the start of the series of parallel obs. line_9: One series of obs will be taken in the CVZ and another roughly in line_10: the orbital plane in each of the time of TWO orbits. Due to the line_11: volume of Science Data the STR has to be dumped after the first line_12: orbit of taking data. The FOC is the primary SI and the PC is the line_13: secondary SI and the Telemetry format is "AN". PC obs are taken line_14: back to back during the orbit following the parallel observations line_15: to get as many data points close to each other. The exectution of line_16: the prop is time critical and must be executed by May 25, 1993 +/- line_17: 1 day. Special scheduling requirement for the orbital plane target line_18: only: Schedule science alignments to begin as close to "orbit noon" as line_19: as possible. (NOT required for the Interactive Acquisition for the line_20: FOC orbital plane target.) ! ! end of abstract general_form_proposers: lname: BALZANO fname: VICKI title: PI inst: SPACE TELESCOPE SCIENCE INSTITUTE country: USA ! lname: BELY fname: PIERRE inst: SPACE TELESCOPE SCIENCE INSTITUTE country: USA ! lname: MIEBACH fname: MANFRED inst: SPACE TELESCOPE SCIENCE INSTITUTE country: USA ! lname: HASAN fname: HASHIMA inst: SPACE TELESCOPE SCIENCE INSTITUTE country: USA ! lname: SCHNEIDER fname: GLENN inst: SPACE TELESCOPE SCIENCE INSTITUTE country: USA ! ! end of general_form_proposers block general_form_text: question: 5 section: 1 line_1: The execution of the proposal is time critical and must be executed line_2: by May 25, 1993 +/- 1 day. Special scheduling requirement for the line_3: orbital plane target (ONLY): Schedule science alignments to begin line_4: as close to "orbit noon" as possible. (NOT required line_5: for the Interactive Acquisition for the FOC orbital plane target.) line_6: The CVS and orbital place target observations should be taken line_7: as close together as possible given the other proposal restrictions. ! !end of general form text general_form_address: lname: BALZANO fname: VICKI category: PI inst: SPACE TELESCOPE SCIENCE INSTITUTE addr_1: 3700 SAN MARTIN DRIVE city: BALTIMORE state: MD country: USA ! ! end of general_form_address records fixed_targets: targnum: 1 name_1: CVZ-FOC descr_1: STAR pos_1: RA=20H 15M 57.360S +/- 0.1S, pos_2: DEC=-61D 49' 43.428" +/- 1", equinox: 2000 pm_or_par: N plate_req: N comment_1: FOC TARGET FOR CVZ. GSID=9086.00349 fluxnum_1: 2 fluxval_1: V=13.84 ! targnum: 2 name_1: CVZ-PC7 descr_1: STAR pos_1: RA=20H 15M 46.721S +/- 0.1S, pos_2: DEC=-61D 43' 47.388" +/- 1", equinox: 2000 pm_or_par: N plate_req: N comment_1: PC TARGET FOR CVZ. GSID=9086.01276 fluxnum_1: 2 fluxval_1: V=12.49 ! targnum: 3 name_1: M11-FOC descr_1: STAR pos_1: RA=18H 51M 17.218S +/- 0.1S, pos_2: DEC=-06D 22' 23.376" +/- 1", equinox: 2000 pm_or_par: N plate_req: N comment_1: FOC TARGET FOR ORBITAL PLANE. comment_2: GSID=5126.05213 fluxnum_1: 2 fluxval_1: V=12.76 ! targnum: 4 name_1: M11-PC6 descr_1: STAR pos_1: RA=18H 50M 55.838S +/- 0.1S, pos_2: DEC=-06D 18' 14.400" +/- 1", equinox: 2000 pm_or_par: N plate_req: N comment_1: PC TARGET FOR ORBITAL PLANE. comment_2: GSID=5126.02663 fluxnum_1: 2 fluxval_1: V=10.82 ! ! end of fixed targets ! No solar system records found ! No generic target records found exposure_logsheet: linenum: 1.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: CYCLE 3 / 1-44; req_2: SEQ 1-2 NO GAP; req_3: INT ACQ FOR 2.0; req_4: ORIENT -73.28D +/- 0D; comment_1: THIS IS THE DECISION EXPOSURE FOR THE comment_2: TA MODE I PROCEDURE TO BE FOLLOWED comment_3: BY A SIP. ! linenum: 2.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 2 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS ! linenum: 3.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 2 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 2.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 4.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 4 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 5.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 2 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 4.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 6.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 6 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 7.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 2 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 6.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 8.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 8 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 9.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 2 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 8.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 10.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 10 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 11.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 2 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 10.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 12.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 12 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 13.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 2 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 12.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 14.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 14 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH ONE PC comment_3: OBSERVATION. ! linenum: 15.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 1 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 14.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 16.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 16 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH ONE PC comment_3: OBSERVATION. ! linenum: 17.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 1 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 16.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 18.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 18 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH ONE PC comment_3: OBSERVATION. ! linenum: 19.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 1 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 18.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 20.000 targname: CVZ-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 20 AS 1 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH ONE PC comment_3: OBSERVATION. ! linenum: 21.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 1 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 20.0 comment_1: READ OUT CCD7 ONLY. ! linenum: 22.000 targname: CVZ-PC7 config: PC opmode: IMAGE aperture: PC7 sp_element: F547M num_exp: 24 time_per_exp: 20S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: AFTER 20 BY 95M +/- 5M; req_2: NON-INT; req_3: SAME POS FOR 22 AS 1; req_4: SAME ORIENT FOR 22 AS 1; comment_1: DO 24 BACK TO BACK PC SCIENCE comment_2: EXPOSURES. READ OUT CCD7 ONLY. ! linenum: 23.000 targname: M11-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M,F1ND num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SEQ 23-24 NO GAP; req_2: INT ACQ FOR 24.0; req_3: ORIENT -115.44D +/- 0D; comment_1: THIS IS THE DECISION EXPOSURE FOR THE comment_2: TA MODE I PROCEDURE FOR THE ORBITAL comment_3: TARGET FOLLOWED BY A SIP. ! linenum: 24.000 targname: M11-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M,F1ND num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 24 AS 23 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 25.000 targname: M11-PC6 config: PC opmode: IMAGE aperture: PC6 sp_element: F547M num_exp: 2 time_per_exp: 4.0S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 24.0 comment_1: READ OUT CCD6 ONLY. ! linenum: 26.000 targname: M11-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M,F1ND num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 26 AS 23 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 27.000 targname: M11-PC6 config: PC opmode: IMAGE aperture: PC6 sp_element: F547M num_exp: 2 time_per_exp: 4.0S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 26.0 comment_1: READ OUT CCD6 ONLY. ! linenum: 28.000 targname: M11-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M,F1ND num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 28 AS 23 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 29.000 targname: M11-PC6 config: PC opmode: IMAGE aperture: PC6 sp_element: F547M num_exp: 2 time_per_exp: 4.0S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 28.0 comment_1: READ OUT CCD6 ONLY. ! linenum: 30.000 targname: M11-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M,F1ND num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 30 AS 23 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 31.000 targname: M11-PC6 config: PC opmode: IMAGE aperture: PC6 sp_element: F547M num_exp: 2 time_per_exp: 4.0S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 30.0 comment_1: READ OUT CCD6 ONLY. ! linenum: 32.000 targname: M11-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M,F1ND num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 32 AS 23 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 33.000 targname: M11-PC6 config: PC opmode: IMAGE aperture: PC6 sp_element: F547M num_exp: 2 time_per_exp: 4.0S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 32.0 comment_1: READ OUT CCD6 ONLY. ! linenum: 34.000 targname: M11-FOC config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F550M,F1ND num_exp: 1 time_per_exp: 300S s_to_n: 1 fluxnum_1: 2 priority: 1 req_1: SAME ORIENT FOR 34 AS 23 comment_1: THIS IS AN FOC SCIENCE EXPOSURE TO comment_2: START IN PARALLEL WITH THE PC comment_3: OBSERVATIONS. ! linenum: 35.000 targname: M11-PC6 config: PC opmode: IMAGE aperture: PC6 sp_element: F547M num_exp: 2 time_per_exp: 4.0S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: PAR WITH 34.0 comment_1: READ OUT CCD6 ONLY. ! linenum: 44.000 targname: M11-PC6 config: PC opmode: IMAGE aperture: PC6 sp_element: F547M num_exp: 16 time_per_exp: 4.0S s_to_n: 1 fluxnum_1: 2 priority: 1 param_1: PRE-FLASH=NO req_1: AFTER 34 BY 95M +/- 5M; req_2: NON-INT; req_3: SAME POS FOR 44 AS 23; req_4: SAME ORIENT FOR 44 AS 23; comment_1: DO 16 BACK TO BACK PC SCIENCE comment_2: EXPOSURES. READ OUT CCD6 ONLY. ! ! end of exposure logsheet ! No scan data records found