! $Id: 4734,v 4.1 1994/07/27 14:36:30 pepsa Exp $ coverpage: title_1: COSTAR/FOC FINE ALIGNMENT proposal_for: SMC/COS pi_title: DR. pi_fname: GEORGE pi_lname: HARTIG pi_inst: STSCI pi_country: USA pi_phone: (410)338-4966 keywords_1: COSTAR, SMOV hours_pri: 4.45 num_pri: 1 foc: Y ! end of coverpage abstract: line_1: The following activities will take place during this proposal. line_3: 1. Perform a 3x3 tilt scan centered on the current best FOC line_4: X-tilt and Y-tilt positions. Take an FOC image at each scan line_5: point. line_6: Perform a fine focus sweep. +/- 2, 1 mm and take an FOC image line_7: at each DOB point. ! ! end of abstract general_form_proposers: lname: TROELTZSCH fname: JOHN mi: R inst: BALL AEROSPACE country: USA ! lname: HARTIG fname: GEORGE inst: SPACE TELESCOPE SCIENCE INSTITUTE country: USA ! lname: JEDRZEJEWSKI fname: ROBERT inst: SPACE TELESCOPE SCIENCE INSTITUTE country: USA ! ! end of general_form_proposers block general_form_text: question: 2 section: 1 line_1: This activity will satisfy the following COSTAR SMOV line_2: Requirements: line_3: 1. Perform FOC fine tilt scan. Take FOC images at 9 locations line_4: in a 3 x 3 grid. line_5: 2. Perform FOC fine focus sweep. Take FOC images at 4 DOB line_6: positions: +/-2mm, +/- 1mm. ! question: 3 section: 1 line_1: An interactive target execution will be executed to acquire line_2: the target into the FOC F/96 aperture. Next, an FOC image will line_3: be taken with the DOB and FOC tilt mechanisms at their current line_4: optimum positions as determined by the COSTAR/FOC Phase Retrieval line_5: test. line_7: The FOC M1 mirror will then be moved to each of the 9 scan line_8: points with an FOC image being taken at each point. The scan line_9: grid is shown below. Each grid point is labeled with an x and y line_10: coordinate (x,y) followed by the number order (#) of the tilt scan line_11: X(x,y)-#. The distance between points is 30arcsec (=4 tilt steps). line_13: X(1,3)-05 X(2,3)-04 X(3,3)-03 line_15: X(1,2)-02 X(2,2)-01 X(3,2)-06 line_17: X(1,1)-09 X(2,1)-08 X(3,1)-07 ! question: 5 section: 1 line_1: Prerequisites: line_2: 1. The first series of the COSTAR/FOC Phase Retrieval Test (4735) line_8: Real-time Requirements: None line_10: Target Selection: 3 targets are provided. They are used in the exposure line_11: logsheet in the preferred order fo BPM16274, HZ21, HZ4. ! question: 7 section: 1 line_1: Engineering data will be reduced using the ESS and the COSTAR line_2: data analysis system to generate standard sorts and plots. line_4: Sorts and plots will be used to: line_5: 1. Verify FOC tilt movements and performance line_6: 2. Verify COSTAR electrical performance line_8: Science data will be analyzed using the COSTAR/FOC data analysis line_9: system. The following analysis will be performed: line_11: 1. Calculate the centroid and encircled energy for each image line_12: and plot the results vs. X-tilt and Y-tilt position. line_13: 2. Run phase retrieval on the most out of focus image line_14: on either side of optimal focus to determine the optical line_15: aberrations (Zernike coefficients). line_16: 3. Use the results of steps 1 and 2 and the COSTAR line_17: opto-mechanical model to determine new positions for line_18: DOB and X and Y Tilt mechanisms. ! question: 7 section: 2 line_1: Certain Data Base Updates: line_2: 1. None. line_4: Possible Data Base Updates: line_5: 1. Update default SHP mirror positions in PDB table file. ! !end of general form text general_form_address: lname: Hartig fname: George category: PI inst: STSCI addr_1: 3700 San Martin Dr city: Baltimore state: MD zip: 21218 country: USA phone: 410 338-4966 ! lname: Jedrzejewski fname: Robert category: CON inst: STSCI addr_1: 3700 San Martin Dr city: Baltimore state: MD zip: 21218 country: USA phone: 410 338-4817 ! lname: Troeltzsch fname: John mi: R inst: Ball Aerospace addr_1: P. O. Box 1062 city: Boulder state: CO zip: 80306 country: USA phone: 303 939-5781 ! ! end of general_form_address records fixed_targets: targnum: 1 name_1: BPM16274 descr_1: J,701,704 pos_1: RA=00H 50M 03.2S +/- 0.1S, pos_2: DEC=-52D 08' 17.4" +/- 1", pos_3: PLATE-ID=02PU equinox: 2000 comment_1: TARGETS ARE LISTED IN PRIORITY comment_2: ORDER. fluxnum_1: 1 fluxval_1: V = 14.20 +/- 0.2 fluxnum_2: 2 fluxval_2: TYPE=DA2 ! targnum: 2 name_1: HZ21 descr_1: J,704 pos_1: RA= 12H 13M 56.42S +/- 0.2S, pos_2: DEC=+32D 56' 30.8" +/- 0.5", pos_3: PLATE-ID=00Y2 equinox: 2000 fluxnum_1: 1 fluxval_1: V = 14.58 +/- 0.2 fluxnum_2: 2 fluxval_2: B-V = -0.45 ! targnum: 3 name_1: HZ4 descr_1: J,704 pos_1: RA=03H 55M 21.70S +/- 0.1S, pos_2: DEC=+09D 47' 18.7" +/- 1", pos_3: PLATE-ID=02HA equinox: 2000 fluxnum_1: 1 fluxval_1: V = 14.52 +/- 0.2 ! ! end of fixed targets ! No solar system records found ! No generic target records found exposure_logsheet: linenum: 1.000 sequence_1: DEFINE sequence_2: FOCIMAGE targname: # config: FOC/96 opmode: IMAGE aperture: 256X256 sp_element: F486N num_exp: 1 time_per_exp: 1000S s_to_n: 20 fluxnum_1: 1 priority: 1 comment_1: STANDARD FOC IMAGE ! linenum: 2.000 targname: BPM16274 config: FOC/96 opmode: ACQ aperture: 512X1024 sp_element: F486N num_exp: 1 time_per_exp: 10M priority: 1 param_1: PIXEL=50X25, req_1: INT ACQ FOR 2.5; req_2: SEQ 2.0-28.0 NO GAP; req_3: CYCLE 4 / 2.0-230.0; req_4: SELECT 1 OF 2-30 OR 102-130 OR req_5: 202-230; COND IF BPM AVAILABLE/ req_6: 2-30; ! linenum: 2.500 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 3.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=-30, param_2: Y-TILT=0, comment_1: -30 ARCSEC X MOVE TO SCAN POINT 2 ! linenum: 4.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 5.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=+30.0, param_2: Y-TILT=+30.0 comment_1: +60 ARCSEC X +30 ARCSEC Y comment_2: MOVE TO SCAN POINT 3 ! linenum: 6.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 7.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=0.0, param_2: Y-TILT=+30.0, comment_1: -30 ARCSEC X MOVE TO SCAN POINT 4 ! linenum: 8.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 9.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=-30.0, param_2: Y-TILT=+30.0, comment_1: -30 ARCSEC X MOVE TO SCAN POINT 5 ! linenum: 10.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 11.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=+30.0, param_2: Y-TILT=0.0, comment_1: +60 ARCSEC X, -30 ARCSEC Y comment_2: MOVE TO SCAN POINT 6 ! linenum: 12.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 13.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=+30.0, param_2: Y-TILT=-30.0 comment_1: -30 ARCSEC Y MOVE TO SCAN POINT 7 ! linenum: 14.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 15.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=0.0, param_2: Y-TILT=-30.0 comment_1: -30 ARCSEC X MOVE TO SCAN POINT 8 ! linenum: 16.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 17.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=-30.0, param_2: Y-TILT=-30.0 comment_1: -30 ARCSEC X MOVE TO SCAN POINT 9 ! linenum: 18.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 comment_1: TILT TO HOME POSITION AFTER comment_2: THIS IMAGE. ! linenum: 19.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=0, param_2: Y-TILT=0, ! linenum: 19.500 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 20.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=-112, comment_1: COSTAR DOB -2MM MOVE ! linenum: 21.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 22.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=-55, comment_1: COSTAR DOB -1MM MOVE ! linenum: 23.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 24.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=+63, comment_1: COSTAR DOB +1MM MOVE ! linenum: 25.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 26.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=+124 comment_1: COSTAR DOB +2MM MOVE ! linenum: 27.000 sequence_1: USE sequence_2: FOCIMAGE targname: BPM16274 ! linenum: 28.000 targname: DARK config: S/C opmode: DATA aperture: NONE num_exp: 1 time_per_exp: 20M priority: 1 req_1: RT ANALYSIS; comment_1: ATTACH INSTR = BDUMPSTR ! linenum: 29.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 30M priority: 1 req_1: REQ UPLINK; req_2: AFTER 27 BY 24H; comment_1: SET COSTAR DOB POSITION ! linenum: 30.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 30M priority: 1 req_1: REQ UPLINK; req_2: AFTER 29; comment_1: SET COSTAR FOC TILTS ! linenum: 102.000 targname: HZ21 config: FOC/96 opmode: ACQ aperture: 512X1024 sp_element: F486N num_exp: 1 time_per_exp: 10M priority: 1 param_1: PIXEL=50X25, req_1: INT ACQ FOR 102.5; req_2: SEQ 102-128 NO GAP; req_3: COND IF BPM NOT AVAILABLE/ req_4: 102-130; ! linenum: 102.500 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 103.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=-30.0, param_2: Y-TILT=0, comment_1: -30 ARCSEC X MOVE TO SCAN POINT 2 ! linenum: 104.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 105.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=+30.0, param_2: Y-TILT=+30.0 comment_1: +60 ARCSEC X +30 ARCSEC Y comment_2: MOVE TO SCAN POINT 3 ! linenum: 106.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 107.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=0.0, param_2: Y-TILT=+30.0, comment_1: -30 ARCSEC X MOVE TO SCAN POINT 4 ! linenum: 108.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 109.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=-30.0, param_2: Y-TILT=+30.0, comment_1: -30 ARCSEC X MOVE TO SCAN POINT 5 ! linenum: 110.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 111.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=+30.0, param_2: Y-TILT=0.0, comment_1: +60 ARCSEC X, -30 ARCSEC Y comment_2: MOVE TO SCAN POINT 6 ! linenum: 112.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 113.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=+30.0, param_2: Y-TILT=-30.0 comment_1: -30 ARCSEC Y MOVE TO SCAN POINT 7 ! linenum: 114.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 115.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=0.0, param_2: Y-TILT=-30.0 comment_1: -30 ARCSEC X MOVE TO SCAN POINT 8 ! linenum: 116.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 117.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=-30.0, param_2: Y-TILT=-30.0 comment_1: -30 ARCSEC X MOVE TO SCAN POINT 9 ! linenum: 118.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 comment_1: FOC TILT TO HOME POSITION comment_2: AFTER THIS IMAGE. ! linenum: 119.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=0, param_2: Y-TILT=0, ! linenum: 119.500 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 120.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=-112 comment_1: COSTAR DOB -2MM MOVE ! linenum: 121.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 122.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=-55, comment_1: COSTAR DOB -1MM MOVE ! linenum: 123.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 124.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=+63, comment_1: COSTAR DOB +1MM MOVE ! linenum: 125.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 126.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=+124, comment_1: COSTAR DOB +2MM MOVE ! linenum: 127.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ21 ! linenum: 128.000 targname: DARK config: S/C opmode: DATA aperture: NONE num_exp: 1 time_per_exp: 20M priority: 1 req_1: RT ANALYSIS; comment_1: ATTACH INSTR = BDUMPSTR ! linenum: 129.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 30M priority: 1 req_1: REQ UPLINK; req_2: AFTER 127 BY 24H; comment_1: SET COSTAR DOB POSITION ! linenum: 130.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 30M priority: 1 req_1: REQ UPLINK; req_2: AFTER 129; comment_1: SET COSTAR FOC TILTS ! linenum: 202.000 targname: HZ4 config: FOC/96 opmode: ACQ aperture: 512X1024 sp_element: F486N num_exp: 1 time_per_exp: 10M priority: 1 param_1: PIXEL=50X25, req_1: INT ACQ FOR 202.5; req_2: SEQ 202.0-228.0 NO GAP; req_3: COND IF HZ21 NOT AVAILABLE/ req_4: 202-230; ! linenum: 202.500 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 203.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=-30.0, param_2: Y-TILT=0, comment_1: -30 ARCSEC X MOVE TO SCAN POINT 2 ! linenum: 204.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 205.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=+30.0, param_2: Y-TILT=+30.0 comment_1: +60 ARCSEC X +30 ARCSEC Y comment_2: MOVE TO SCAN POINT 3 ! linenum: 206.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 207.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=0.0, param_2: Y-TILT=+30.0, comment_1: -30 ARCSEC X MOVE TO SCAN POINT 4 ! linenum: 208.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 209.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=-30.0, param_2: Y-TILT=+30.0, comment_1: -30 ARCSEC X MOVE TO SCAN POINT 5 ! linenum: 210.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 211.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=+30.0, param_2: Y-TILT=0.0, comment_1: +60 ARCSEC X, -30 ARCSEC Y comment_2: MOVE TO SCAN POINT 6 ! linenum: 212.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 213.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=+30.0, param_2: Y-TILT=-30.0 comment_1: -30 ARCSEC Y MOVE TO SCAN POINT 7 ! linenum: 214.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 215.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=0.0, param_2: Y-TILT=-30.0 comment_1: -30 ARCSEC X MOVE TO SCAN POINT 8 ! linenum: 216.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 217.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=-30.0, param_2: Y-TILT=-30.0 comment_1: -30 ARCSEC X MOVE TO SCAN POINT 9 ! linenum: 218.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 comment_1: COSTAR FOC TILTS TO HOME comment_2: POSITION AFTER THIS IMAGE. ! linenum: 219.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: X-TILT=0, param_2: Y-TILT=0 ! linenum: 219.500 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 220.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=-112 comment_1: COSTAR DOB -2MM MOVE ! linenum: 221.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 222.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=-55, comment_1: COSTAR DOB -1MM MOVE ! linenum: 223.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 224.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=+63, comment_1: COSTAR DOB +1MM MOVE ! linenum: 225.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 226.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 0.0S priority: 1 param_1: FOCUS=+124, comment_1: COSTAR DOB +2MM MOVE ! linenum: 227.000 sequence_1: USE sequence_2: FOCIMAGE targname: HZ4 ! linenum: 228.000 targname: DARK config: S/C opmode: DATA aperture: NONE num_exp: 1 time_per_exp: 20M priority: 1 req_1: RT ANALYSIS; comment_1: ATTACH INSTR = BDUMPSTR ! linenum: 229.000 targname: NONE config: COSTAR opmode: DOB num_exp: 1 time_per_exp: 30M priority: 1 req_1: REQ UPLINK; req_2: AFTER 227 BY 24H; comment_1: SET COSTAR DOB POSITION ! linenum: 230.000 targname: NONE config: COSTAR opmode: FOC num_exp: 1 time_per_exp: 30M priority: 1 req_1: REQ UPLINK; req_2: AFTER 229; comment_1: SET COSTAR FOC TILTS ! ! end of exposure logsheet ! No scan data records found