! $Id: 4708,v 4.1 1994/07/27 14:31:01 pepsa Exp $ coverpage: title_1: WFPC-2 SAFE TO HOLD MODE proposal_for: SME/WF2 pi_fname: AMIT pi_lname: SEN pi_inst: JPL pi_country: USA pi_phone: 818-354-5933 hours_pri: 0.50 wf_pc: Y realtime: Y ! end of coverpage abstract: line_1: This proposal transitions the WPFC2 to HOLD mode. WFPC2 is expected to line_2: already be in hold mode by completion of the in-bay functional tests. line_3: This proposal provides a contingency transition only. ! ! end of abstract general_form_proposers: lname: SEN fname: AMIT inst: JPL country: USA ! ! end of general_form_proposers block general_form_text: question: 2 section: 1 line_1: This is a contingency WFPC2 SMOV activity. ! question: 3 section: 1 line_1: Although WFPC2 is expected to already be in HOLD mode at the start of SMOV, line_2: this proposal will provide for the transition to HOLD mode if it's needed. ! question: 5 section: 1 line_1: Special scheduling requirements: line_2: Prerequisites: If WFPC2 is not already in HOLD mode, this will be the FIRST line_3: WFPC2 SMOV activity. All other activities require that the WFPC2 has line_4: successfully been transitioned from SAFE to HOLD mode. line_6: REALTIME Requirements: Realtime engineering telemetry is required line_7: during this activity. line_9: There is an absolute minimum seperation of 1 hour between lines 3 and 4 line_10: (turning on the CCD heaters and turning on the heatpipe heaters). line_11: This will be a CARD item. ! !end of general form text general_form_address: lname: SEN fname: AMIT category: PI inst: JPL addr_1: 4800 OAK GROVE DRIVE addr_2: MAIL STOP 179-225 city: PASADENA state: CA zip: 91109 country: USA phone: 818-354-5933 ! ! end of general_form_address records ! No fixed target records found ! No solar system records found ! No generic target records found exposure_logsheet: linenum: 1.000 targname: DARK config: S/C opmode: POINTING aperture: V1 num_exp: 1 time_per_exp: 1S priority: 1 req_1: SEQ 1-4; req_2: CYCLE 4/1-4; comment_1: SI = WFPC2:OFFLINE. ! linenum: 2.000 targname: DARK config: S/C opmode: DATA aperture: NONE num_exp: 1 time_per_exp: 30M priority: 1 req_1: NON-INT; req_2: RT ANALYSIS; comment_1: SI = WFPC2:OFFLINE, comment_2: INSTRUCTION = SURECOVER, comment_3: QESIPARM: UVCAL=IN, comment_4: LEAVE AFMS OFF. ! linenum: 3.000 targname: DARK config: S/C opmode: POINTING aperture: V1 num_exp: 1 time_per_exp: 4M priority: 1 comment_1: SI START=WFPC2:OFFLINE, SI WFPC2:HOLD, comment_2: INSTRUCTION = EUCCDHEAT, comment_3: QESIPARM: CCDHEAT=ON, ! linenum: 4.000 targname: DARK config: S/C opmode: POINTING aperture: V1 num_exp: 1 time_per_exp: 4M priority: 1 req_1: AFTER 3 BY 90M +/- 30M; comment_1: TURN HEATPIPE THAW HEATERS ON. comment_2: SET FILTER 555W ! ! end of exposure logsheet ! No scan data records found