! File: 3393C.PROP ! Database: PEPDB ! Date: 19-FEB-1994:06:12:06 coverpage: title_1: EARTH-CALIB-7: WF F785LP, PC F658N, PC F469N proposal_for: SV/WFC pi_title: PROF pi_fname: J. pi_mi: A. pi_lname: WESTPHAL pi_inst: CALTECH pi_country: USA pi_phone: (818) 356-4900 keywords_1: CALIBRATION, FLAT FIELDS wf_pc: X pi_position: J. A. WESTPHAL ! end of coverpage abstract: line_1: This test is to take "uniform illuminated" pictures of line_2: the earth. These data will be used to obtain the "instrument line_3: signature" for flat field corrections. line_4: This is an attempt to get the broad band filters at either line_5: terminator crossing. ! ! end of abstract general_form_proposers: lname: WESTPHAL fname: J. mi: A. inst: WF/PC IDT country: USA ! ! end of general_form_proposers block general_form_text: question: 2 section: 0 line_1: line_2: This series of observations is required to characterize line_3: the WF/PC and remove the instrument signature. ! question: 3 section: 0 line_1: line_2: These data are taken to obtain the flat field properties line_3: of the WF/PC instrument. line_4: This proposal contains 2 types of scheduling units of line_5: different duration. The two units are interchangeable. ! question: 5 section: 1 line_1: SV Prerequisite: line_2: If UV flood is lost, scheduling of these exposures line_3: should be reconsidered. ! !end of general form text general_form_address: lname: WESTPHAL fname: J. mi: A. category: PI inst: CALTECH ! lname: SHAYA fname: EDWARD inst: U. OF MARYLAND addr_1: DEPT. OF PHYSICS/ASTRONOMY city: COLLEGE PARK state: MD zip: 20742 country: USA phone: (301) 405-6044 ! lname: FABER fname: SANDRA inst: LICK OBSERVATORY addr_1: U. OF CALIFORNIA city: SANTA CRUZ state: CA zip: 95064 country: USA phone: (408) 459-2944 ! lname: DANIELSON fname: ED inst: CALTECH addr_1: M/S 170-25 city: PASADENA state: CA zip: 91125 country: USA phone: (818) 356-6861 telex: EDANIELSON ! ! end of general_form_address records ! No fixed target records found ! No solar system records found ! No generic target records found exposure_logsheet: linenum: 2.100 sequence_1: DEF SEQ7-1 targname: EARTH-CALIB config: WFC opmode: IMAGE aperture: ALL sp_element: F785LP num_exp: 2 time_per_exp: 0.11S priority: 1 param_1: CR-SPLIT=NO, param_2: PRE-FLASH=NO req_1: SEQ 2.1-2.4 NO GAP; req_2: CYCLE 0 / 2.1-21 comment_1: SEQUENCE SHOULD FIT INTO A comment_2: SINGLE EARTH OCCULTATION. comment_3: BEST IF 2.1 OBSERVES GREYEARTH ! linenum: 2.200 sequence_1: DEF SEQ7-1 targname: EARTH-CALIB config: PC opmode: IMAGE aperture: ALL sp_element: F658N num_exp: 1 time_per_exp: 1.60S priority: 1 param_1: CR-SPLIT=NO, param_2: PRE-FLASH=NO ! linenum: 2.300 sequence_1: DEF SEQ7-1 targname: EARTH-CALIB config: PC opmode: IMAGE aperture: ALL sp_element: F469N num_exp: 1 time_per_exp: 1.40S priority: 1 param_1: CR-SPLIT=NO, param_2: PRE-FLASH=NO ! linenum: 2.400 sequence_1: DEF SEQ7-1 targname: EARTH-CALIB config: WFC opmode: IMAGE aperture: ALL sp_element: F785LP num_exp: 1 time_per_exp: 0.11S priority: 1 param_1: CR-SPLIT=NO, param_2: PRE-FLASH=NO ! linenum: 3.100 sequence_1: DEF SEQ7-2 targname: EARTH-CALIB config: WFC opmode: IMAGE aperture: ALL sp_element: F785LP num_exp: 2 time_per_exp: 0.11S priority: 1 param_1: CR-SPLIT=NO, param_2: PRE-FLASH=NO req_1: SEQ 3.1-3.3 NO GAP; comment_1: SEQUENCE SHOULD FIT INTO comment_2: A SINGLE EARTH OCCULTATION. comment_3: BEST IF 3.1 OBSERVES comment_4: GREY-EARTH ! linenum: 3.200 sequence_1: DEF SEQ7-2 targname: EARTH-CALIB config: PC opmode: IMAGE aperture: ALL sp_element: F658N num_exp: 1 time_per_exp: 1.60S priority: 1 param_1: CR-SPLIT=NO, param_2: PRE-FLASH=NO ! linenum: 3.300 sequence_1: DEF SEQ7-2 targname: EARTH-CALIB config: PC opmode: IMAGE aperture: ALL sp_element: F469N num_exp: 1 time_per_exp: 1.40S priority: 1 param_1: CR-SPLIT=NO, param_2: PRE-FLASH=NO ! linenum: 10.000 sequence_1: USE SEQ7-1 ! linenum: 11.000 sequence_1: USE SEQ7-2 ! linenum: 12.000 sequence_1: USE SEQ7-1 ! linenum: 13.000 sequence_1: USE SEQ7-2 ! linenum: 14.000 sequence_1: USE SEQ7-1 ! linenum: 15.000 sequence_1: USE SEQ7-2 ! linenum: 16.000 sequence_1: USE SEQ7-1 ! linenum: 17.000 sequence_1: USE SEQ7-2 ! linenum: 18.000 sequence_1: USE SEQ7-1 ! linenum: 19.000 sequence_1: USE SEQ7-2 ! linenum: 20.000 sequence_1: USE SEQ7-1 ! linenum: 21.000 sequence_1: USE SEQ7-2 ! ! end of exposure logsheet ! No scan data records found