! File: 2914C.PROP ! Database: PEPDB ! Date: 17-FEB-1994:21:25:48 coverpage: title_1: WF/PC CYCLE 1 CALIBRATION: UV PREP II proposal_for: CAL/WFC pi_title: DR. pi_fname: JOHN pi_mi: W. pi_lname: MACKENTY pi_inst: STSCI pi_country: USA pi_phone: (301) 338-4559 ! end of coverpage abstract: line_1: This calibration is a continuation of UV PREP I. line_3: A UV calibration will be preformed to determine the line_4: quantum efficency of the detectors. This test should line_5: be coupled to each science observation that plans to do line_6: photometric measurements with filters F122M, F157W, line_7: F194W, or G200L (in the UV). line_9: The UV sequence should look like: line_10: UV PREP I ... Science Observations ... UV PREP II ! ! end of abstract general_form_proposers: lname: MACKENTY fname: JOHN mi: W. inst: STSCI country: USA ! ! end of general_form_proposers block general_form_text: question: 2 section: 0 line_1: This calibration sequence monitors the camera performance line_2: in the UV following the science observations which were line_3: preceeded by UV PREP I. The SV minimum line_4: plan calibrations are used to tie the UV spectra to the line_5: individual filters. ! question: 3 section: 0 line_1: See UV PREP I ! question: 5 section: 0 line_1: Real-time contact is not required. line_3: SI C&DH operational format AN. ! !end of general form text general_form_address: lname: MACKENTY fname: JOHN mi: W. title: DR. category: PI inst: ST SCI ! lname: MACKENTY fname: JOHN mi: W. inst: STSCI country: USA phone: (301) 338-4559 ! ! end of general_form_address records fixed_targets: targnum: 1 name_1: A+81266 descr_1: UV SPECTROPHOTOMETRIC STANDARD pos_1: RA= 09H21M29S +/-1S, pos_2: DEC= 81D43'00" +/-10", equinox: 2000 fluxnum_1: 1 fluxval_1: V=12.1 +/-0.5 ! ! end of fixed targets ! No solar system records found ! No generic target records found exposure_logsheet: linenum: 10.000 sequence_1: USE sequence_2: UVBASELINE req_1: CYCLE 1/10-180; ! linenum: 110.000 sequence_1: DEFINE sequence_2: UVBASELINE targname: A+81266 config: WFC opmode: IMAGE aperture: W1 sp_element: G200L num_exp: 1 time_per_exp: 5S priority: 1 req_1: SEQ 110-180 NO GAP; req_2: SEQ 110-140 NON-INT; comment_1: ONLY READOUT 1 CCD. ! linenum: 120.000 sequence_1: ^ targname: ^ config: ^ opmode: ^ aperture: W2 sp_element: ^ num_exp: ^ time_per_exp: ^ priority: ^ comment_1: ONLY READOUT 1 CCD. ! linenum: 130.000 sequence_1: ^ targname: ^ config: ^ opmode: ^ aperture: W3 sp_element: ^ num_exp: ^ time_per_exp: ^ priority: ^ comment_1: ONLY READOUT 1 CCD. ! linenum: 140.000 sequence_1: ^ targname: ^ config: ^ opmode: ^ aperture: W4 sp_element: ^ num_exp: ^ time_per_exp: ^ priority: ^ comment_1: ONLY READOUT 1 CCD. ! linenum: 150.000 sequence_1: ^ targname: ^ config: PC opmode: ^ aperture: P5 sp_element: ^ num_exp: ^ time_per_exp: 25S priority: ^ req_1: SEQ 150-180 NON-INT; comment_1: ONLY READOUT 1 CCD. ! linenum: 160.000 sequence_1: ^ targname: ^ config: ^ opmode: ^ aperture: P6 sp_element: ^ num_exp: ^ time_per_exp: ^ priority: ^ comment_1: ONLY READOUT 1 CCD. ! linenum: 170.000 sequence_1: ^ targname: ^ config: ^ opmode: ^ aperture: P7 sp_element: ^ num_exp: ^ time_per_exp: ^ priority: ^ comment_1: ONLY READOUT 1 CCD. ! linenum: 180.000 sequence_1: ^ targname: ^ config: ^ opmode: ^ aperture: P8 sp_element: ^ num_exp: ^ time_per_exp: ^ priority: ^ comment_1: ONLY READOUT 1 CCD. ! ! end of exposure logsheet ! No scan data records found