! File: 2749C.PROP ! Database: PEPDB ! Date: 17-FEB-1994:10:57:58 coverpage: title_1: HSP RIU POLLING ON/OFF TEST HSP-I2 proposal_for: SV/HSP pi_title: DR. pi_fname: ROBERT pi_mi: C. pi_lname: BLESS pi_inst: UNIVERSITY OF WISCONSIN pi_country: USA pi_phone: (608) 262-1715 keywords_1: SCIENCE VERIFICATION hours_pri: 2.00 hsp: Y pi_position: PROF. OF ASTRONOMY ! end of coverpage abstract: line_1: This test takes dark count data from line_2: two HSP detectors, IDT #3 (vis) and the line_3: PMT and with high voltage on and off and line_4: with RIU polling on and off. The purpose line_5: of this test is to verify the RIU noise line_6: is eliminaged if RIU polling is off. line_7: Note: This is RPSS file # TBD. Revision line_8: history: Richards 1/4/89 line_9: This is based on 1379, HSP-i1 ! ! end of abstract general_form_proposers: lname: RICHARDS fname: EVAN title: MR. mi: E. inst: UNIVERSITY OF WISCONSIN country: USA ! lname: DOLAN fname: JOSEPH title: DR. mi: F. inst: GODDARD SPACE FLIGHT CENTER country: USA ! lname: BLESS fname: ROBERT title: DR. mi: C. inst: UNIVERSITY OF WISCONSIN country: USA ! ! end of general_form_proposers block general_form_text: question: 2 section: 1 line_1: The justification for the proposed test is to line_2: determine the effect of the RIU noise on the line_3: detector dark count for two HSP detectors, line_4: IDT #3 and the PMT. The IDT #3 dark count line_5: is observed at one of the locations observed line_6: in HSP-i1. The dark count data are obtained line_7: with high voltage on and off and with RIU line_8: polling on and off. This test is considered a line_9: "delta SV" test to be run if RIU noise is line_10: observed in HSP-i1. This test also serves as line_11: a test case for the development of ground system line_12: software. line_13: The in-flight results will be compared with the line_14: data from HSP-i1 and data from ground testing. ! question: 3 section: 1 line_1: This test is to be performed during dark time, line_2: and during the PMT portion of the test the ST line_3: should be pointing at the dark earth. line_4: 1) IDT3: the HSP is to be configured in the line_5: single-color, one aperture mode (HSP/x, SINGLE) line_6: with the detector at nominal high voltage and line_7: PAD settings. The detector is to be sampled at line_8: the central cathode position. This position has line_9: the following detector coordinates: line_10: (H,V) = (2000,1900) line_11: An integration of 5 minutes in length, line_12: sampling at 0.1 second samples, is to be line_13: obtained with detector high voltage on. Then line_14: a second sampling is done with high voltage off. line_15: The third and fourth 5 minute integrations are line_16: performed with RIU polling turned off. line_17: 2) PMT: Operating at the nominal high voltage line_18: the dark current is to be sampled for 5 minutes line_19: with high voltage on and 5 minutes with high line_20: voltage off. The RIU polling is then turned line_21: and the observations repeated. Data are to be line_22: taken in the ALL format. There are a total of line_23: eight 5 minute observations in this test. ! question: 5 section: 1 line_1: OV This is a repeat of an OV activity. It is line_2: assumed that initial detector turn-on and all line_3: other early OV tests have been completed. line_5: This is an line_6: internal test and no external targets are line_7: observed. Dark time is required for the entire line_8: test, and for the PMT portion of the test it line_9: is required that the ST be pointing at the dark line_10: earth. To perform the test, it is assumed that line_11: each detector has been successfully powered up line_12: for 30 minutes, which is the case if the line_13: standard stabilization times are used. ! question: 6 section: 1 line_1: Dark time and non-SAA passage are line_2: required for this test. ! question: 7 section: 1 line_1: The data reduction is planned as follows: line_2: For both of the detectors the mean line_3: dark count rate (digital mode) will be line_4: determined and compared to the data obtained line_5: from HSP-i1. The data taken with RIU polling line_6: on will be compared to the data taken with line_7: RIU polling off to confirm that RIU noise can line_8: be completely eliminated by turning off RIU line_9: polling. ! question: 10 section: 1 line_1: Data reduction and analysis will be supported at line_2: the Space Astronomy Lab at the University of line_3: Wisconsin in Madison. ! !end of general form text general_form_address: lname: BLESS fname: ROBERT mi: C category: PI inst: UNIVERSITY OF WISCONSIN addr_1: WASHBURN OBSERVATORY addr_2: 475 NORTH CHARTER STREET addr_3: UNIVERSITY OF WISCONSIN city: MADISON state: WI zip: 53706 country: USA ! lname: DOLAN fname: JOSEPH mi: F. title: DR. category: CON inst: GSFC addr_1: CODE 681 city: GREENBELT state: MD zip: 20771 country: USA phone: (301) 286-6846 ! lname: RICHARDS fname: EVAN mi: E. category: CON inst: UNIVERSITY OF WISCONSIN addr_1: 475 N. CHARTER STREET city: MADISON state: WI zip: 53706 country: USA phone: (608) 263-6775 ! ! end of general_form_address records fixed_targets: targnum: 1 name_1: PMT-DARK-SKY descr_1: DARK SKY POSITION FOR PMT DARKS pos_1: RA = 16H 27M 11S +/- .01S, pos_2: DEC = -24D 19' 14" +/- .01" equinox: 2000 comment_1: SELECT 1 OF THESE TARGETS AS THE comment_2: PMT DARK SKY POINTING ! targnum: 2 name_1: PMT-DARK-SKY-2 descr_1: DARK SKY POSITION FOR PMT DARKS pos_1: RA = 3H 46.3M +/- 0.1M, pos_2: DEC = 32D 49' +/- 1' equinox: 1975 ! targnum: 3 name_1: PMT-DARK-SKY-3 descr_1: DARK SKY POSITION FOR PMT DARKS pos_1: RA = 6H 5.9M +/- 0.1M, pos_2: DEC = 19D 42' +/- 1' equinox: 1975 ! targnum: 4 name_1: PMT-DARK-SKY-4 descr_1: DARK SKY POSITION FOR PMT DARKS pos_1: RA = 16H 55.7M +/- 0.1M, pos_2: DEC = -22D 42' +/- 1' equinox: 1975 ! targnum: 5 name_1: PMT-DARK-SKY-5 descr_1: DARK SKY POSITION FOR PMT DARKS pos_1: RA = 18H 31.3M +/- 0.1M, pos_2: DEC = -9D 10' +/- 1' equinox: 1975 ! targnum: 6 name_1: PMT-DARK-SKY-6 descr_1: DARK SKY POSITION FOR PMT DARKS pos_1: RA = 21H 23.1M +/- 0.1M, pos_2: DEC = 50D 6' +/- 1' equinox: 1975 ! ! end of fixed targets ! No solar system records found ! No generic target records found exposure_logsheet: linenum: 1.000 sequence_1: DEFINE sequence_2: DARK-IDT targname: DARK config: # opmode: SINGLE aperture: # sp_element: # num_exp: 1 time_per_exp: 300S priority: 1 param_1: #, param_2: #, param_3: #, param_4: #, req_1: DARK TIME; req_2: CYCLE 0/1-12; ! linenum: 5.000 sequence_1: DEFINE sequence_2: DARK-PMT targname: PMT-DARK-SKY config: HSP/PMT/VIS opmode: SPLIT aperture: 1.0 sp_element: F750W/F320N num_exp: 1 time_per_exp: 300S priority: 1 param_1: DATA-FORMAT=ALL, param_2: SAMPLE-TIME=0.1, param_3: ANALOG-SCALE=10, req_1: DARK TIME; req_2: SEQ 5-6; comment_1: SAMPLE PMT DARK CURRENT comment_2: AT NOMINAL HV ! linenum: 6.000 sequence_1: ^ targname: ^ config: ^ opmode: ^ aperture: ^ sp_element: ^ num_exp: ^ time_per_exp: ^ priority: ^ param_1: ^ param_2: ^ param_3: ^ param_4: HV-GAIN=OFF, req_1: DARK TIME; comment_1: SAMPLE PMT DARK CURRENT WITH HIGH comment_2: VOLTAGE OFF. ! linenum: 7.000 sequence_1: USE sequence_2: DARK-IDT config: HSP/VIS aperture: 1.0-A sp_element: F355M param_1: DATA-FORMAT=ALL, param_2: SAMPLE-TIME=0.1, param_3: ANALOG-SCALE=10, param_4: HV-GAIN=G1.0, req_1: SEQ 7-7.3 NO GAP; comment_1: SAMPLE VIS IDT. comment_2: (H,V) = (2000,1900) comment_3: RIU POLLING ON ! linenum: 7.100 sequence_1: USE sequence_2: DARK-IDT config: HSP/VIS aperture: 1.0-A sp_element: F355M param_1: ^, param_2: ^, param_3: ^, param_4: HV-GAIN=OFF, comment_1: SAMPLE VIS IDT. comment_2: (H,V) = (2000,1900) comment_3: HIGH VOLTAGE OFF comment_4: RIU POLLING ON ! linenum: 7.200 sequence_1: USE sequence_2: DARK-IDT config: HSP/VIS aperture: 1.0-A sp_element: F355M param_1: DATA-FORMAT=ALL, param_2: SAMPLE-TIME=0.1, param_3: ANALOG-SCALE=10, param_4: HV-GAIN=G1.0, req_1: SEQ 7-7.3 NO GAP; comment_1: SAMPLE VIS IDT. comment_2: (H,V) = (2000,1900) comment_3: RIU POLLING OFF ! linenum: 7.300 sequence_1: USE sequence_2: DARK-IDT config: HSP/VIS aperture: 1.0-A sp_element: F355M param_1: ^, param_2: ^, param_3: ^, param_4: HV-GAIN=OFF, comment_1: SAMPLE VIS IDT. comment_2: (H,V) = (2000,1900) comment_3: HIGH VOLTAGE OFF comment_4: RIU POLLING OFF ! linenum: 11.000 sequence_1: USE sequence_2: DARK-PMT req_1: SEQ 11-12 NO GAP; comment_1: SAMPLE PMT. comment_2: RIU POLLING IS ON ! linenum: 12.000 sequence_1: USE sequence_2: DARK-PMT comment_1: SAMPLE PMT comment_2: RIU POLLING IS OFF ! ! end of exposure logsheet ! No scan data records found