! File: 2105C.PROP ! Database: PEPDB ! Date: 17-FEB-1994:00:52:48 coverpage: title_1: FOC F/48 TRANSITION TO OPERATIONAL MODE (FOC009A) proposal_for: OV/FOC pi_fname: R. pi_mi: J. pi_lname: LAURANCE pi_inst: ESA/ESTEC pi_country: NETHERLANDS pi_phone: 31-1719-83516 hours_pri: 16.00 realtime: X ! end of coverpage abstract: line_1: The first task to be carried out in the electrical verification of the f/48 line_2: chain is to transition to operational mode and to observe the thermal stability line_3: and the image stability in that mode. ! ! end of abstract general_form_proposers: lname: LAURANCE fname: R. mi: J. inst: ESA/FOC country: NETHERLANDS esa: X ! ! end of general_form_proposers block general_form_text: question: 3 section: 1 line_1: The first step in the electrical verification of the f/48 detector is line_2: transition into the operational mode and to take a series of images using the line_3: internal calibration source over a period of 12 hours. This allows the line_4: detector to become thermally stabilized and the image stability will be tracked line_5: over this period. line_7: Real time monitoring capability will be needed for 30 minutes line_8: during the phase when the detector high voltage is switched on for the first line_9: time. During the rest of the 9 hour period (12H if overheads are line_10: included), dumps of the images should be made every 3 hours, as a minimum. ! question: 5 section: 1 line_1: Real time monitoring capability will be needed for 30 minutes line_2: during the phase when the detector high voltage is switched on for the first line_3: time. line_5: FOC should be powered down to STANDBY mode 5 minutes before entering regions line_6: in excess of 10 protons/cm2/sec with E>50 Mev and should remain in STANDBY mode line_7: until 15 minutes after exit from the SAA. line_9: This proposal should be executed after proposals 2104, 2151 and 2152, FOC005, line_10: FOC006 and FOC007. line_12: Initiate FOC Warm-Up A/1 Mode 3.5H +/- 0.5H before start of line 10. ! question: 7 section: 1 line_1: The exposures will be analyzed to assess image stability and the engineering line_2: telemetry will be examined to determine the thermal stability. ! !end of general form text general_form_address: lname: LAURANCE fname: R. mi: J. category: PI inst: ESA/ESTEC addr_1: POSTBUS 299 city: 2200 AG NOORDWIJK country: NETHERLANDS phone: 1719-83516 telex: 39098 ! ! end of general_form_address records fixed_targets: targnum: 1 name_1: DUMMY pos_1: RA = 0H 0M 0S +/- 1", pos_2: DEC = 0D 0' 0" +/-1" equinox: 1950 ! ! end of fixed targets ! No solar system records found ! No generic target records found exposure_logsheet: linenum: 10.000 targname: DARK config: S/C opmode: DATA aperture: NONE num_exp: 1 time_per_exp: 30M priority: 1 param_1: REALTIME=DATA req_1: SEQ 10-60 NO GAP; comment_1: TRANSITION FOC/48 TO OPERATE WITH comment_2: REALTIME MONITORING. ! linenum: 11.000 targname: INTFLAT config: FOC/48 opmode: RESEAU aperture: 512X1024 num_exp: 2 time_per_exp: 900S priority: 1 param_1: LED=GREEN-2, param_2: PIXEL=50X25, param_3: LED-STEP=4, req_1: NON-INT / 11-12; comment_1: PERFORM IMMEDIATELY AFTER THE HIGH comment_2: VOLTAGE TRANSITION. ! linenum: 12.000 targname: DARK config: FOC/48 opmode: IMAGE aperture: 512X1024 sp_element: CLEAR num_exp: 1 time_per_exp: 900S priority: 1 param_1: PIXEL=50X25, comment_1: PERFORM IMMEDIATELY AFTER THE HIGH comment_2: VOLTAGE TRANSITION. ! linenum: 13.000 targname: DARK config: S/C opmode: DATA aperture: NONE num_exp: 1 time_per_exp: 10M priority: 1 param_1: REALTIME=CMD, comment_1: UPLINK OPPORTUNITY FOR MOC TO ISSUE comment_2: PSTOL IN THE EVENT OF A PROBLEM WITH comment_3: HV TURN ON. ! linenum: 15.000 targname: INTFLAT config: FOC/48 opmode: RESEAU aperture: 512X1024 num_exp: 1 time_per_exp: 15M priority: 1 param_1: PIXEL=50X25, param_2: LED=GREEN-2, param_3: LED-STEP=4, req_1: RT ANALYSIS; ! linenum: 20.000 targname: ^ config: ^ opmode: ^ aperture: ^ sp_element: ^ num_exp: 10 time_per_exp: ^ priority: ^ ! linenum: 30.000 targname: ^ config: ^ opmode: ^ aperture: ^ sp_element: ^ num_exp: 1 time_per_exp: ^ priority: ^ param_1: ^ req_1: RT ANALYSIS; comment_1: PROVIDE RT DOWNLINK TO EXAMINE IMAGES comment_2: AT 3H INTERVALS. ! linenum: 40.000 targname: ^ config: ^ opmode: ^ aperture: ^ sp_element: ^ num_exp: 11 time_per_exp: ^ priority: ^ param_1: ^ ! linenum: 50.000 targname: ^ config: ^ opmode: ^ aperture: ^ sp_element: ^ num_exp: 1 time_per_exp: ^ priority: ^ param_1: ^ req_1: RT ANALYSIS; ! linenum: 60.000 targname: ^ config: ^ opmode: ^ aperture: ^ sp_element: ^ num_exp: 12 time_per_exp: ^ priority: ^ param_1: ^ ! ! end of exposure logsheet ! No scan data records found