! File: 1501C.PROP ! Database: PEPDB ! Date: 16-FEB-1994:20:49:01 coverpage: title_1: HSP DATA INTEGRITY TEST HSP-IE proposal_for: OV pi_title: PROF. pi_fname: ROBERT pi_mi: C. pi_lname: BLESS pi_inst: UNIVERSITY OF WISCONSIN pi_country: USA hours_pri: 0.42 hsp: Y realtime: Y ! end of coverpage abstract: line_1: This internal test serves as a test of special bus director operations. line_2: Using a special HSP system controller bus director program, simulated line_3: science data are transmitted from the polarimeter IDT (POL, IDT#1) at the line_4: maximum data rate. The data stream will have an embedded pattern (a "ramp") line_5: which will allow data mutations and dropouts to be detected. line_6: Note: This is RPSS file 1501. Revision history: Richards 4/13/88, line_7: Slovak 5/20/88, Richards 6/29/88 line_8: Translated to V2 proposal instructions, Laurent 2/7/89 line_9: RPSS software version 6.2. ! ! end of abstract general_form_proposers: lname: RICHARDS fname: E. mi: E. inst: UNIVERSITY OF WISCONSIN country: USA ! lname: PERCIVAL fname: J. mi: W. inst: UNIVERSITY OF WISCONSIN country: USA ! lname: BLESS fname: ROBERT mi: C. inst: UNIVERSITY OF WISCONSIN country: USA ! ! end of general_form_proposers block general_form_text: question: 2 section: 1 line_1: The justification for this internal test is to verify that science data can be line_2: successfully transmitted by HSP at maximum transfer rates. This test is line_3: essential to verify that the HSP can be used in modes where the high speed data line_4: link must be utilized. ! question: 3 section: 1 line_1: This test requires no external targets. The test is performed by executing the line_2: following steps with IDT#1 (POL): line_3: 1) Make the oldhold-to-newhold transition. Note that the High Volts are off. line_4: Configure the SD link for 1Mbit data transmission. line_5: Load and run the 1 Mbit Special bus director program using the tape line_6: recorder to store the data. line_8: Make the newhold-to-oldhold transition. line_9: 2) Make the oldhold-to-newhold transition. Note that the High Volts are off. line_10: Configure the SD link for 1Mbit data transmission. line_11: Load and run the 1 Mbit Special bus director program using a realtime line_12: downlink to transmit the data. line_13: Make the newhold-to-oldhold transition. line_14: 3) Make the oldhold-to-newhold transition. High Volts are off. line_15: Configure the SD link for 32 Kbit data transmission. line_16: Load and run the 32 Kbit Special bus director program line_17: using the tape recorder to store the data. line_18: Make the newhold-to-oldhold transition. line_19: 4) Make the oldhold-to-newhold transition. High Volts are off. line_20: Configure the SD link for 4 Kbit data transmission. line_21: Load and run the 4 Kbit Special bus director program line_22: using the tape recorder to store the data. line_23: Make the newhold-to-oldhold transition. ! question: 5 section: 1 line_1: HSP tests iA though iD must be completed before this test is begun. line_2: Only one segment of this test needs to be done in real-time. ! question: 5 section: 2 line_1: The data collections in question 3 can be performed in any order and not all of line_2: them need be performed together. The pieces may be constructed as separate line_3: command loads if necessary. ! question: 7 section: 1 line_1: Data reduction will consist of analyzing the collected simulated science data. line_2: The data will be searched for deviations from the imbedded pattern (a "ramp") line_3: to detect any mutations or dropouts. ! question: 10 section: 1 line_1: Data reduction and analysis for this test will be supported at the University of line_2: Wisconsin Space Astronomy Laboratory. ! !end of general form text general_form_address: lname: BLESS fname: ROBERT mi: C. category: PI inst: UNIVERSITY OF WISCONSIN addr_1: 475 NORTH CHARTER STREET city: MADISON state: WI zip: 53706 country: USA phone: (608)262-1715 ! lname: RICHARDS fname: EVAN mi: E. category: CON inst: UNIVERSITY OF WISCONSIN addr_1: SSEC addr_2: 1225 W. DAYTON STREET city: MADISON state: WI zip: 53706 country: USA phone: (608)263-6675 ! lname: PERCIVAL fname: JEFFREY mi: W. category: CON inst: UNIVERSITY OF WISCONSIN addr_1: SPACE AST. LAB. addr_2: 1150 UNIVERSITY AVENUE city: MADISON state: WI zip: 53706 country: USA phone: (608)263-8686 ! ! end of general_form_address records ! No fixed target records found ! No solar system records found ! No generic target records found exposure_logsheet: linenum: 1.000 targname: DARK config: HSP/POL opmode: SINGLE aperture: POL0 sp_element: F216M num_exp: 1 time_per_exp: 12M priority: 1 param_1: SAMPLE-TIME = .00001172, param_2: DATA-FORMAT = BYTE, req_1: GROUP 1-4 WITHIN 5D; comment_1: OLDHOLD-TO-NEWHOLD. HIGH VOLTS ARE comment_2: OFF. CONFIGURE 1MBPS SD LINK. RUN comment_3: THE 1MBPS SPECIAL BUS DIRECTOR PGM comment_4: USING POL DETECTOR. STORE DATA ON comment_5: TAPE RECORDER. NEWHOLD-TO-OLDHOLD. comment_6: (DARK = RAMP FOR TARGET).(VBK040). ! linenum: 2.000 targname: DARK config: HSP/POL opmode: SINGLE aperture: POL0 sp_element: F216M num_exp: 1 time_per_exp: 3M priority: 1 param_1: SAMPLE-TIME = .00001172, param_2: DATA-FORMAT = BYTE, req_1: RT ANALYSIS; comment_1: OLDHOLD-TO-NEWHOLD. HIGH VOLTS ARE comment_2: OFF. CONFIGURE 1MBPS SD LINK. RUN comment_3: THE 1MBPS SPECIAL BUS DIRECTOR PGM comment_4: USING POL DETECTOR. TRANSMIT DATA comment_5: REALTIME. NEWHOLD-TO-OLDHOLD. comment_6: (DARK = RAMP FOR TARGET).(VBK040). ! linenum: 3.000 targname: DARK config: HSP/POL opmode: SINGLE aperture: POL0 sp_element: F216M num_exp: 1 time_per_exp: 5M priority: 1 param_1: SAMPLE-TIME = .00032031, param_2: DATA-FORMAT = BYTE, comment_1: OLDHOLD-TO-NEWHOLD. HIGH VOLTS ARE comment_2: OFF. CONFIGURE 32KBPS SD LINK. RUN comment_3: THE 32KBPS SPECIAL BUS DIRECTOR PGM comment_4: USING POL DETECTOR. STORE DATA ON comment_5: TAPE RECORDER. NEWHOLD-TO-OLDHOLD. comment_6: (DARK = RAMP FOR TARGET).(VBK041). ! linenum: 4.000 targname: DARK config: HSP/POL opmode: SINGLE aperture: POL0 sp_element: F216M num_exp: 1 time_per_exp: 5M priority: 1 param_1: SAMPLE-TIME = .0025625, param_2: DATA-FORMAT = BYTE, comment_1: OLDHOLD-TO-NEWHOLD. HIGH VOLTS ARE comment_2: OFF. CONFIGURE 4KBPS SD LINK. RUN comment_3: THE 4KBPS SPECIAL BUS DIRECTOR PGM comment_4: USING POL DETECTOR. STORE DATA ON comment_5: TAPE RECORDER. NEWHOLD-TO-OLDHOLD. comment_6: (DARK = RAMP FOR TARGET).(VBK042). ! ! end of exposure logsheet ! No scan data records found