coverpage:

  title_1:         WF/PC OV LINEARITY TEST
    proposal_for:  OV/WFC
    pi_fname:      JAMES
    pi_mi:         A.
    pi_lname:      WESTPHAL
    pi_inst:       CALTECH
! end of coverpage

abstract:

    line_1:        This engineering test is performed to determine
    line_2:        the linearity and noise properties of all eight WFPC  detectors
    line_3:        Tests to characterize quantum efficiency hysteresis
    line_4:        are performed.  Images through the five most used emission
    line_5:        line filters will be taken to verify ground based calibrations.
    line_6:        This test must be done after TECs turned on.
    line_8:        EXPOSURE LINES 7 AND 16 CHANGED FROM NON-INT TO NO GAP BECAUSE OF
    line_9:        TRANS ERRORS.

!
! end of abstract

general_form_proposers:

  lname:           DANIELSON
    fname:         G.
    mi:            E.
    inst:          CALTECH
    country:       USA

!

  lname:           WESTPHAL
    fname:         JAMES
    mi:            A.
    inst:          CALTECH
    country:       USA

!

  lname:           GUNN
    fname:         JAMES
    mi:            E.
    inst:          PRINCETON UNIVERSITY
    country:       USA

!
! end of general_form_proposers block

general_form_text:

  question:        2
    section:       0
    line_1:        These on-orbit tests are necessary to determine the
    line_2:        linearity and noise response of the WF/PC detectors. Quantum
    line_3:        efficiency hysteresis is also measured.
    line_4:        Images of M-42 will be obtained through the set of the most
    line_5:        commonly used narrow band filters.  By comparing these
    line_6:        images with ground-based spectrophotometry we will derive
    line_7:        an absolute calibration for these filters which is
    line_8:        independent of ST observations of standard stars,
    line_9:        thereby providing a check on our ability to calibrate
    line_10:       other narrow band filters using standard star data.
    line_11:       Comparison with ground based imagery will provide
    line_12:       a check on our narrow band flats.

!

  question:        3
    section:       1
    line_1:        Filter F555W will be selected, and two bias frames taken.
    line_2:        A sequence of 5 observations of one target follows, during
    line_3:        which exposures are taken of increasing duration.
    line_4:        This is followed by a QEH measurement
    line_5:        consisting of three rapid exposures using F439W, a wait of
    line_6:        20 minutes, and two subsequent rapid exposures.  The test
    line_7:        is performed for both the WFC and the PC; however, the
    line_8:        exposures for the PC sequence are approximately five times
    line_9:        the duration of those for the WFC sequence.  A series of exposures using
    line_10:       narrow emission line filters is done on this same target to
    line_11:       derive accurate emission line intensity calibrations in the WFC.
    line_12:       TECs must be on and the CCDs as cold as -80.

!

  question:        5
    section:       1
    line_1:        Real-time contact is not required for commanding and data reduction.

!

  question:        6
    section:       1
    line_1:

!

  question:        8
    section:       1
    line_1:

!
!end of general form text

general_form_address:

  lname:           DANIELSON
    fname:         G.
    mi:            E.
    category:      COI
    inst:          CALTECH
    addr_1:        DIVISION OF GEOLOGICAL & PLANETARY SCIENCES
    city:          PASADENA
    state:         CA
    zip:           91125
    country:       USA
    phone:         (818) 356-6861

!

  lname:           WESTPHAL
    fname:         JAMES
    mi:            A.
    category:      PI
    inst:          CALTECH
    addr_1:        DIVISION OF GEOLOGICAL & PLANETARY SCIENCE
    city:          PASADENA
    state:         CA
    zip:           91125
    country:       USA
    phone:         (818) 356-4900

!

  lname:           GUNN
    fname:         JAMES
    mi:            E.
    category:      DEP
    inst:          PRINCETON UNIVERSITY
    addr_1:        ASTROPHYSICAL SCIENCE
    addr_2:        PEYTON HALL
    city:          PRINCETON
    state:         NJ
    zip:           08540
    country:       USA
    phone:         (609) 452-3802

!
! end of general_form_address records

fixed_targets:

    targnum:       1
    name_1:        M-42-WF
    name_2:        ORION NEBULA
    descr_1:       DIFFUSE OBJECT
    pos_1:         RA=05H 32M 43.5S +/- 0.1S,
    pos_2:         DEC=-05D 23' 13" +/- 1"
    equinox:       1950

!

    targnum:       2
    name_1:        M-42-PC
    name_2:        ORION NEBULA
    descr_1:       DIFFUSE OBJECT
    pos_1:         RA=05H 32M 51.2S +/- 0.1S,
    pos_2:         DEC=-05D 26' 13" +/- 1"
    equinox:       1950

!
! end of fixed targets

! No solar system records found

! No generic target records found

exposure_logsheet:

    linenum:       1.000
    sequence_1:    DEFINE
    sequence_2:    LNTSTWF
    targname:      BIAS
    config:        WFC
    opmode:        IMAGE
    aperture:      ALL
    sp_element:    NONE
    num_exp:       2
    time_per_exp:  0S
    priority:      1
    param_1:       CR-SPLIT=NO
    req_1:         SEQ 1-6 NO GAP;
    req_2:         NON-INT / 1-6;
    comment_1:     TEST MUST BE DONE WITH TECS ON

!

    linenum:       2.000
    sequence_1:    ^
    targname:      #
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    F555W
    num_exp:       ^
    time_per_exp:  30S
    priority:      ^
    param_1:       ^

!

    linenum:       3.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    ^
    num_exp:       ^
    time_per_exp:  60S
    priority:      ^
    param_1:       ^

!

    linenum:       4.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    ^
    num_exp:       ^
    time_per_exp:  120S
    priority:      ^
    param_1:       ^

!

    linenum:       5.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    ^
    num_exp:       ^
    time_per_exp:  260S
    priority:      ^
    param_1:       ^

!

    linenum:       6.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    ^
    num_exp:       ^
    time_per_exp:  500S
    priority:      ^
    param_1:       ^

!

    linenum:       7.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    F439W
    num_exp:       2
    time_per_exp:  300S
    priority:      1
    param_1:       ^
    req_1:         SEQ 7-8 NO GAP;
    comment_1:     QEH TEST, TWO EXPOSURES ARE MADE
    comment_2:     IN AS RAPID SUCCESSION AS POSSIBLE
    comment_3:     DO NOT CLEAR SPECTRAL ELEMENT

!

    linenum:       8.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    ^
    num_exp:       2
    time_per_exp:  300S
    priority:      1
    param_1:       ^
    req_1:         AFTER 7 BY 35M +/- 5M
    comment_1:     MIDDLE OF QEH TEST,  EXPOSURES
    comment_2:     IN AS RAPID SUCESSION AFTER THE
    comment_3:     20 MINUTE WAIT.

!

    linenum:       9.000
    sequence_1:    USE
    sequence_2:    LNTSTWF
    targname:      M-42-WF

!

    linenum:       10.000
    sequence_1:    DEFINE
    sequence_2:    LNTSTPC
    targname:      BIAS
    config:        PC
    opmode:        IMAGE
    aperture:      ALL
    sp_element:    NONE
    num_exp:       2
    time_per_exp:  0S
    priority:      1
    param_1:       CR-SPLIT=NO
    req_1:         SEQ 10-14 NO GAP;
    req_2:         NON-INT / 10-17;

!

    linenum:       11.000
    sequence_1:    ^
    targname:      #
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    F555W
    num_exp:       ^
    time_per_exp:  100S
    priority:      ^
    param_1:       ^

!

    linenum:       12.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    ^
    num_exp:       ^
    time_per_exp:  200S
    priority:      ^
    param_1:       ^

!

    linenum:       13.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    ^
    num_exp:       ^
    time_per_exp:  400S
    priority:      ^
    param_1:       ^

!

    linenum:       14.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    ^
    num_exp:       ^
    time_per_exp:  800S
    priority:      ^
    param_1:       ^

!

    linenum:       16.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    F439W
    num_exp:       2
    time_per_exp:  400S
    priority:      1
    param_1:       ^
    req_1:         SEQ 16-17 NO GAP;
    comment_1:     MUST BE DONE ON NEXT ORBIT AFTER 15
    comment_2:     QEH TEST, TWO EXPOSURES ARE MADE
    comment_3:     IN AS RAPID SUCCESSION AS POSSIBLE
    comment_4:     DO NOT CLEAR SPECTRAL ELEMENT

!

    linenum:       17.000
    sequence_1:    ^
    targname:      ^
    config:        ^
    opmode:        ^
    aperture:      ^
    sp_element:    ^
    num_exp:       2
    time_per_exp:  400S
    priority:      1
    param_1:       ^
    req_1:         AFTER 16 BY 32M +/- 5M;

!

    linenum:       18.000
    sequence_1:    USE
    sequence_2:    LNTSTPC
    targname:      M-42-PC

!

    linenum:       20.000
    sequence_1:    DEFINE
    sequence_2:    EMISLN
    targname:      #
    config:        #
    opmode:        IMAGE
    aperture:      ALL
    sp_element:    #
    num_exp:       1
    time_per_exp:  1S
    priority:      1
    req_1:         NON-INT

!

    linenum:       21.000
    sequence_1:    USE
    sequence_2:    EMISLN
    targname:      M-42-WF
    config:        WFC
    sp_element:    F656N
    time_per_exp:  X200

!

    linenum:       22.000
    sequence_1:    USE
    sequence_2:    EMISLN
    targname:      M-42-WF
    config:        WFC
    sp_element:    F673N
    time_per_exp:  X600

!

    linenum:       23.000
    sequence_1:    USE
    sequence_2:    EMISLN
    targname:      M-42-WF
    config:        WFC
    sp_element:    F487N
    time_per_exp:  X600

!

    linenum:       24.000
    sequence_1:    USE
    sequence_2:    EMISLN
    targname:      M-42-WF
    config:        WFC
    sp_element:    F502N
    time_per_exp:  X300

!

    linenum:       25.000
    sequence_1:    USE
    sequence_2:    EMISLN
    targname:      M-42-WF
    config:        WFC
    sp_element:    F375N
    time_per_exp:  X600

!

    linenum:       26.000
    sequence_1:    USE
    sequence_2:    EMISLN
    targname:      M-42-WF
    config:        WFC
    sp_element:    F487N
    time_per_exp:  X600

!

    linenum:       27.000
    sequence_1:    USE
    sequence_2:    EMISLN
    targname:      M-42-WF
    config:        WFC
    sp_element:    F658N
    time_per_exp:  X600

!
! end of exposure logsheet